Serial multi-daylight stack with equal loaded area in every used opening: the same force transmits through the stack. Do not multiply by the number of openings. Unequal loading, several panels side-by-side, frame design, cylinder loads and safety margins require engineering review.
Assumed example: 2440 × 1220 mm at 1 MPa gives 2976.8 kN, approximately 303.55 metric tonne-force. This is a force conversion, not a recommended pressure recipe.
Inputs and units
Enter the loaded length and width in millimetres and the target specific pressure in megapascals (MPa). Use the area actually subjected to pressure, not automatically the full platen dimensions: panel size, loading arrangement, and any unloaded margins affect the effective area.
The calculation assumes a uniform pressure over one rectangular loaded area. For irregular loading or multiple unequal loads, simplify only when the resulting estimate remains meaningful; confirm the press arrangement with an engineer.
| Input or result | Unit | Meaning |
|---|---|---|
| Loaded length and width | mm | Effective loaded dimensions |
| Specific pressure | MPa | Force per unit area |
| Total force | kN | Estimated force on loaded area |
| Force equivalent | tonne-force | kN converted by 9.80665 |
Formula and conversion
Calculate loaded area as length × width in mm². Because 1 MPa equals 1 N/mm², total force in kilonewtons is loaded area × pressure ÷ 1,000. Convert kilonewtons to tonne-force by dividing by 9.80665. Keep the distinction clear: MPa is specific pressure; kN and tonne-force are total force.
Hypothetical calculation
Assume a loaded area of 1,000 mm × 2,000 mm and a target pressure of 1 MPa. Area is 2,000,000 mm², so estimated force is 2,000 kN, or about 203.9 tonne-force. This is a hypothetical planning example, not a recommended pressure or press rating.
Multi-daylight interpretation
For a stacked multi-daylight press with equal loaded area transmitted through the press in series, do not multiply the calculated force by the number of openings. Each opening provides production capacity, but it does not create a simple multiplier for total press force. Actual cylinder arrangement, frame design, and load distribution require engineering confirmation.
Use the estimate in specification
Treat the output as a preliminary selection estimate. Confirm the effective loaded area, required process pressure, platen and frame design, and hydraulic configuration against the application before specifying equipment. We help plywood mills specify and source press equipment and configurations; calculator results alone do not verify machine suitability.
Questions about this configuration
What is the difference between specific pressure and press force?
Specific pressure describes force per unit area, expressed here in MPa. Press force is the total force over the loaded area, expressed in kN or tonne-force.
Should I use platen area or panel area?
Use the effective area carrying the load for the calculation. Platen dimensions may differ from the loaded area, so confirm the actual loading pattern and dimensions.
Do more openings require proportionally more force?
Not in the simple series model for equal loaded areas in a multi-daylight press. Do not multiply force by openings; confirm the specific press design and loading conditions.